Products
Coronary interventions
Peripheral interventions
Structural heart diseases
Auxiliary devices and accessories
Neurovascular interventions
Aortic endoprosthetics
Embolization
About us News Careers Contacts
+7 (495) 956-83-16 info@raymed.ru

Overview

The Solaris self-expanding stent graft consists of the stent itself and the stent delivery system. The stent is made of an extremely elastic metal alloy (nitinol) fully encapsulated by a polytetrafluoroethylene (PTFE) membrane along its entire length, except at the prosthesis ends, where 3 radiopaque tantalum markers are positioned to delineate the stent margins.
It is intended for endovascular lumen patency maintenance and blood flow improvement in aneurysms and lesions of the iliofemoral arterial segment.

Solaris brochurePDF · opens full screen

Specifications

The Solaris self-expanding stent graft nitinol frame is manufactured by laser cutting a nitinol tube.
Nitinol alloys (nickel-titanium) provide a high degree of stent graft flexibility.

Excellent Visualization: 3 radiopaque tantalum markers are located at the following sites: outer tube tip, catheter tip, and distal inner tube.

Pull-Back and OTW Delivery System:
-Hydrophilic Coating provides enhanced navigation with reduced frictional resistance against the vessel wall,
-Anti-Jumping Mechanism prevents sudden stent jumping/premature deployment,
-Soft Flexible Tip

Delivery System Length: 130 cm
Stent Diameter (mm): 5, 6, 7, 8, 9
Stent Length (mm): 40, 60, 80, 100

Clinical trials

<ul>
<li data-list="bullet"><strong><a href="https://raymed.ru/#popup:embedcode1">Combination of BeGraft and Solaris Stent Grafts for the Covered Endovascular Reconstruction of Aortic Bifurcation&mdash;BS-CERAB Technique</a></strong></li>
</ul>
<p>Enrique M. San Norberto 1,*, &Aacute;lvaro Revilla 1, Jos&eacute; A. Brizuela 1, Isabel Del Blanco 1, &Aacute;ngel Flores 2 and James H. Taylor 3<br><br></p>
<ul>
<li data-list="bullet"><strong><a href="https://raymed.ru/#popup:embedcode2">Safety and efficacy of a new covered stent in hemodialysis vascular access outflow stenosis: Article reuse guidelines: A Brazilian multicenter retrospective study</a></strong></li>
</ul>
<p>&nbsp;</p>
<ul>
<li data-list="bullet"><strong><a href="https://raymed.ru/#popup:embedcode3">True Isolated Deep Femoral Artery Aneurysm Treated with Endovascular Technique: Case Report and Literature Review.</a></strong></li>
</ul>
<p>Rafael de Athayde Soares M.D, PhD*; Marcus Vinicius Martins Cury M.D, PhD; Aline Yoshimi Futigami M.D<br><br><span style="font-size: 20px;">Hospital do Servidor Publico Estadual de S&atilde;o Paulo, Iamspe, Brazil.</span><br><span style="font-size: 20px;">*Corresponding Author: Rafael de Athayde Soares.</span></p>

Have questions?

We'll find the device
for your case

Send us a request — a specialist will get back to you about availability, documentation and delivery terms.

Contact us
+7 (495) 956-83-16 info@raymed.ru Mon-Fri. 9:00 – 18:00